Prerequisite

The following describes how to set up a SIP provider when using an individual number connection.

  1. Go to Assistants -> PBX -> Trunks -> New.

  2. Select SIP Provider under Connection Type.

  3. Click Next.

Assistants -> PBX -> Trunks -> New-> <SIP Provider>

Proceed as follows to save the login information of the SIP provider:

Note

No STUN server may be configured when accessing the Internet via an internal or external DSL modem or a gateway with SIP proxy.

For certain SIP providers, a STUN server must be configured for gateways without SIP proxy and established full-cone Network Address Translation (NAT).

  1. Enter a name for the SIP provider under Name, e.g. Sipgate_Plus_1 .

  2. Enter your provider's Authentication ID (SIP-ID), e. g. 1527861e0 .

  3. Enter the Password you received from your VoIP provider.

  4. For User Name, enter the name that your VoIP provider has sent you, e. g. 1527861e0 . This is the SIP-ID for the providers Sipgate, 1&1, QSC and Toplink.

  5. Enter an IP address or a domain name as the SIP Registrar.

    • For Sipgate Basic/Plus: sipgate.de

    • For 1&1: sip.1und1.de

    • For QSC-IPfonie basic: sip.qsc.de

    • When connecting the Deutsche Telekom Call & Surf Comfort IP connection: tel.t-online.de

    • For Toplink: toplink-voice.de

  6. Use Add under Individual Number (MSN) to create a new entry.

    Enter the number that your VoIP provider has given you under Individual Number (MSN), e.g. 4911148797640 .

    Enter a name for the connection under Displayed Name, e.g. Sipgate_1 . This is displayed on the system telephone for incoming calls.

    Note

    Several numbers can be configured here for the providers QSC-IPfonie basic and Toplink.

    For the providers Sipgate Basic/Plus, 1&1 and Deutsche Telekom, an additional SIP connection with separate SIP account data must be created for each additional number provided by the SIP provider. In order to enable outgoing calls to be made via other numbers or SIP connections, additional authorisation classes should be configured under Numbering -> User Settings-> Authorisation Classes.

  7. Use Add under Authorisation Class to create a new entry and select an authorisation class, e.g. Default CoS .

  8. Enable Generate International Number and Generate National Number.

  9. Leave the remaining settings unchanged and confirm them with OK.

    After the system is successfully registered with the SIP provider, the status display of the respective SIP connection changes to .