OIDNameTypeAccess
.1SlotINTEGERR
.2UnitINTEGERR
.3ClockStatusENUMR
.4ClockMasterENUMR
.5MasterPrioINTEGERRW
.10ChangesCounterR

Slot
description not available

Range: 0 to 30

Unit
Identification number of the used unit.

Range: -1 to 31

ClockStatus
shows wether this board can supply a clock signal to the internal PCM-Highway. ready: this board can supply a clock signal not_ready: this board can't supply a clock signal

Enumerations:

  • ready (1)
  • not-ready (2)
ClockMaster
shows the status of this board. candidate: this board can become PCM Highway master master: this board is PCM Highway master

Enumerations:

  • candidate (1)
  • master (2)
MasterPrio
Priority during PCM-Highway master election. A small value results in high priority; the candidate with highest priority wins the election. Prio 128 (lowest priority) lets the PCM-Highway master use its own clock (instead of using network clock).

Range: 0 to 128

Changes
counts how often sysPCMClockMaster has changed.