>> MIB - Management Information Base

>> Table: mpsTrunkGroupPOTSTable - (.1.3.6.1.4.1.272.4.53.3.6.1)

Description: This table contains advanced information of the external pots trunk groups.

mpsTrunkGroupPOTSTable
OIDNameTypeAccess
.1IndexTrunkGroupIndexRW
.2DialingTypeENUMRW
.3Wait2DialINTEGERRW
.4BusytoneDetectionENUMRW
.5BusytoneTimeSliceINTEGERRW
.6ClipENUMRW
.7ChargeFrequencyENUMRW
.8EndOfDialINTEGERRW
.9AdminStatusENUMD
.10FaxSwitchIndexFaxSwitchIndexOrZeroRW
.11UefsENUMRW

Index
A unique value for each trunk group.

Range: 1 to 65535

DialingType
Type of dialling, DTMF and pulse dialing.

Enumerations:

  • none (1)
  • mfv (2)
  • iwv (3)
Wait2Dial
Time slice in seconds, before digits will be send to trunk. Set to 0: dial tone detection is on.
BusytoneDetection
This value determine if busystone detection is on (true) or off (false).

Enumerations:

  • true (1)
  • false (2)
BusytoneTimeSlice
Max time slice in seconds, to detect the busytone.
Clip
Number display (CLIP).

Enumerations:

  • none (1)
  • mfv (2)
  • dtmf (3)
ChargeFrequency
This value determine the frequency of the charge pulse for POTS trunk groups

Enumerations:

  • no (1)
  • f12khz (2)
  • f16khz (3)
EndOfDial
End of dial time slice in seconds.
AdminStatus
Just for MIB entry deletion.

Enumerations:

  • enable (1)
  • delete (2)
FaxSwitchIndex
A unique value for each fax switch.

Range: 0 to 65535

Uefs
This value determine if 'DDI on POTS' (UEFS) is on (true) or off (false).

Enumerations:

  • true (1)
  • false (2)


MIB Reference to Software Version 10.2.12 generated on 2023/08/29. Provided by webmaster@bintec-elmeg.com
Copyright ©2023 by bintec elmeg GmbH