>> MIB - Management Information Base

>> Table: mpsTerminalTable - (.1.3.6.1.4.1.272.4.53.14.1.1)

Description: This table contains information about terminal endpoints.

mpsTerminalTable
OIDNameTypeAccess
.1IndexTerminalIndexRW
.2IfIndexInterfaceIndexOrZeroRW
.3PhoneTypeENUMRW
.4TypeENUMRW
.5DescrDisplayStringRW
.6AdminStatusENUMD
.7DoorIntercomDoorIntercomIndexOrZeroRW
.8IPSystelPortINTEGERR
.9InterfaceTypeENUMRW
.10OperStatusENUMR
.11MacAddressMacAddressRW
.12OEMTypeENUMRW

Index
A unique value for each terminal.

Range: 1 to 65535

IfIndex
Reference to mpsDeviceTable. 0 = no reference.

Range: 0 to 2147483647

PhoneType
Select the phone type of the terminal: standard (1) : standard terminal systemphone (2) : the terminal is a system phone vms (3) : internal Voice Mail Server oem-phone (4) : the terminal is a OEM phone.

Enumerations:

  • standard (1)
  • systemphone (2)
  • vms (3)
  • oem-phone (4)
Type
This varibale contains the terminal type: telephone(1) : 'normal' phone answering-machine(2): answering machine voice-mail(3) : external voice mail server ermergency-phone(4) : allow ermergency calls with high priority

Enumerations:

  • telephone (1)
  • answering-machine (2)
  • voice-mail (3)
  • emergency-phone (4)
Descr
A textual description of the terminal endpoint.

Length: 0 to 20

AdminStatus
Admin status of the terminal. Set to 'delete' to delete the whole entry.

Enumerations:

  • enable (1)
  • delete (2)
  • disable (3)
  • hidden (4)
DoorIntercom
This variable contains the number of the door intercom, refer to mpsDoorIntercomIndex in mpsDoorIntercomTable, only valid for mpsTerminalPhoneType = standard and mpsTerminalType = telephone.

Range: 0 to 10

IPSystelPort
This variable contains the RTP port number for IP system phone.
InterfaceType
This variable contains the interface type, for which type of interface this terminal can be used.

Enumerations:

  • isdn (1)
  • voip (2)
  • pots (3)
OperStatus
Operational status of the terminal.

Enumerations:

  • up (1)
  • down (2)
  • licMissing (3)
MacAddress
This variable contains the MAC address of the IP terminal.

Length: 6 to 6

OEMType
OEM device type of the terminal e.g. Siemens OpenStage, Gigaset...

Enumerations:

  • none (1)
  • openstage (2)
  • gigaset (3)


MIB Reference to Software Version 10.2.12 generated on 2023/08/29. Provided by webmaster@bintec-elmeg.com
Copyright ©2023 by bintec elmeg GmbH