>> MIB - Management Information Base

>> Table: mpsSysUserConfig - (.1.3.6.1.4.1.272.4.53.1.5)

mpsSysUserConfig
OIDNameTypeAccess
.1PINDisplayStringRW
.2ExternPINDisplayStringRW
.3FacilitiesBITSRW
.4CoSENUMRW
.5PBXModeENUMRW
.6NightGroupModeINTEGERRW
.7NightDoorIntercomModeINTEGERRW
.8NightTrunkModeINTEGERRW
.9NightExtensionModeINTEGERRW
.10NightGlobalReRouteModeINTEGERRW
.11DayGlobalReRouteModeINTEGERRW
.12NightAlarmInputModeINTEGERRW

PIN
This variable contains the system PIN code for configuration. 'none' = inactive (can not be dialed).

Length: 4 to 4

ExternPIN
This variable contains the system PIN code for remote control.

Length: 6 to 6

Facilities
System facilities. (1) enabled or (0) disabled: remoteConfig : Remote switching/ remote control. remoteAccess : Remote access. callRecordPrinting: Print call data records.

Enumerations:

  • remoteConfig (0)
  • remoteAccess (1)
  • callRecordPrinting (2)
CoS
This variable contains the current Class Of Service mode.

Enumerations:

  • standard (1)
PBXMode
This variable contains the current PBX mode.

Enumerations:

  • day (1)
  • night (2)
NightGroupMode
This variable contains the active group mode when the mpsSysConfigPBXMode = night. 0 = night mode for groups is off, individual settings used (day).

Range: 0 to 4

NightDoorIntercomMode
This variable contains the active DoorIntercom mode when variable mpsSysConfigPBXMode is set to night. Value 0 means night mode for door intercom units is off, individual settings used (day).

Range: 0 to 4

NightTrunkMode
This variable contains the active trunk mode when variable mpsSysConfigPBXMode is set to night and mpsTrunkNumberTarget is set to re-route. 0 = night mode for trunk rerouting is off, individual settings used (day).

Range: 0 to 4

NightExtensionMode
This variable contains the active extension mode when variable mpsSysConfigPBXMode is set to night and rerouting is active. 0 = night mode for extension is off, individual settings used (day).

Range: 0 to 4

NightGlobalReRouteMode
This variable contains the active reroute mode when variable mpsSysConfigPBXMode is set to night and global rerouting is available. 0 = night mode for global rerouting is off, individual settings used (day).

Range: 0 to 4

DayGlobalReRouteMode
This variable contains the active global reroute mode when variable mpsSysConfigPBXMode is set to day and global rerouting is available.

Range: 1 to 4

NightAlarmInputMode
This variable contains the active alarm input mode when variable mpsSysConfigPBXMode is set to night. 0 = night mode for alarm input is off, so use the individual settings.

Range: 0 to 2


MIB Reference to Software Version 10.2.12 generated on 2023/08/29. Provided by webmaster@bintec-elmeg.com