>> MIB - Management Information Base

>> Table: mpsExtensionABTable - (.1.3.6.1.4.1.272.4.53.6.5.1)

Description: This table contains the additional information of the analog extension.

mpsExtensionABTable
OIDNameTypeAccess
.1IndexExtensionIndexRW
.2ModeENUMRW
.3GatewayNumberINTEGERRW
.4DialingTypeENUMRW
.5ChargePulseENUMRW
.6ClipENUMRW
.7ClipOffHookENUMRW
.8CnipENUMRW
.9FlashTimeENUMRW
.10DoorIntercomDoorIntercomIndexOrZeroRW
.11DoorIntercomTimerINTEGERRW
.12AdminStatusENUMD

Index
A unique value for additional analog extension settings.

Range: 1 to 65535

Mode
You can configure each analog port to accept a different terminal device. Additional settings or special functions may be required depending on the type of terminal device. Terminal device types which require special functions / applications can be set at some analog connections. Set to delete, to discard the whole entry.

Enumerations:

  • none (1)
  • telephone (2)
  • fax (3)
  • answering-machine (4)
  • modem (5)
  • multi-port (6)
  • moh (7)
  • tfe-123d12 (8)
  • tfe-other (9)
  • tfe-doorline (10)
  • announcement (11)
  • voice-mail-system (12)
  • alarm-line (13)
  • tfe-adapter (14)
  • moh-anouncement (15)
  • tfe-123d12-4bells (16)
  • tfe-others-4bells (17)
  • gateway (18)
GatewayNumber
This variable contains the gateway number, if mpsExtensionABMode=gateway.
DialingType
Type of dialling, DTMF and pulse dialing.

Enumerations:

  • none (1)
  • mfv (2)
  • iwv (3)
ChargePulse
If your analog terminal devices support the display of cost and charge information you can set the transmission of charge pulses at the corresponding connections.

Enumerations:

  • true (1)
  • false (2)
Clip
Number display (CLIP).

Enumerations:

  • none (1)
  • mfv (2)
  • dtmf (3)
ClipOffHook
Number display (CLIP off Hook).

Enumerations:

  • true (1)
  • false (2)
Cnip
Name display (CNIP).

Enumerations:

  • true (1)
  • false (2)
FlashTime
This variable contains the analogue flash time in milliseconds.

Enumerations:

  • m100 (1)
  • m200 (2)
  • m300 (3)
  • m400 (4)
  • m500 (5)
  • m600 (6)
  • m700 (7)
  • m800 (8)
  • m900 (9)
  • m1000 (10)
DoorIntercom
This variable contains the number of the door intercom.

Range: 0 to 10

DoorIntercomTimer
This variable contains the length of timer in seconds for open door.
AdminStatus
Jsut for delete.

Enumerations:

  • enable (1)
  • delete (2)


MIB Reference to Software Version 10.2.12 generated on 2023/08/29. Provided by webmaster@bintec-elmeg.com