>> MIB - Management Information Base

>> Table: mpsCallListConfig - (.1.3.6.1.4.1.272.4.53.17.2)

mpsCallListConfig
OIDNameTypeAccess
.1AccountCallsENUMRW
.2AccountAcceptedENUMRW
.3MaxUserEntriesINTEGERRW
.4MaxSystemEntriesINTEGERRW
.5SystemCountCounter32R

AccountCalls
This value determines which calls are to be accounted.

Enumerations:

  • none (1)
  • incoming-only (2)
  • all (3)
AccountAccepted
Defines whether accepted (connected) calls should be accounted. If set to false only missed calls are collected.

Enumerations:

  • true (1)
  • false (2)
MaxUserEntries
Maximum count of call list entries for each user.

Range: 10 to 200

MaxSystemEntries
Maximum count of system call list entries.

Range: 10 to 1000

SystemCount
Counter of current system call list entries.


MIB Reference to Software Version 10.2.12 generated on 2023/08/29. Provided by webmaster@bintec-elmeg.com