Index |
A unique value for the IMA Group. Range: 1 to 2147483647 |
Symmetry |
Symmetry of the IMA group. Enumerations: - symmetricOperation (1)
- asymmetricOperation (2)
- asymmetricConfiguration (3)
|
MinNumTxLinks |
Minimum number of transmit links required to be Active for the IMA group to be in the Operational state. Range: 1 to 32 |
MinNumRxLinks |
Minimum number of receive links required to be Active for the IMA group to be in the Operational state. Range: 1 to 32 |
TxFrameLength |
The frame length to be used by the IMA group in the transmit direction. Can only be set when the IMA group is startup. Enumerations: - m32 (32)
- m64 (64)
- m128 (128)
- m256 (256)
|
DiffDelayMax |
The maximum number of milliseconds of differential delay among the links that will be tolerated on this interface. |
AlphaValue |
This indicates the 'alpha' value used to specify the number of consecutive invalid ICP cells to be detected before moving to the IMA Hunt state from the IMA Sync state. Range: 1 to 2 |
BetaValue |
This indicates the 'beta' value used to specify the number of consecutive errored ICP cells to be detected before moving to the IMA Hunt state from the IMA Sync state. Range: 1 to 5 |
GammaValue |
This indicates the 'gamma' value used to specify the number of consecutive valid ICP cells to be detected before moving to the IMA Sync state from the IMA PreSync state. Range: 1 to 5 |
ErrorsLinkDown |
This indicates the threshold of the number of ATM header errors per 100000 ATM cells, at which a link is inhibited. The number is compared with average value of received ATM header errors in the last time. The length of the considered time interval is configured in imaGroupErrorIntervalLinkDown. Range: 0 to 100000 |
ErrorIntervalLinkDown |
This indicates the duration of the measure interval in seconds for the ATM header error counter. That is used for calculating an average, which is then compared with the imaGroupErrorsLinkDown value. Range: 15 to 3600 |
ErrorsLinkUp |
This indicates the threshold of the number of ATM header errors per 100000 ATM cells, at which a link is enabled again. The number is compared with average value of received ATM header errors in the last time. The length of the considered time interval is configured in imaGroupErrorIntervalLinkUp. Range: 0 to 100000 |
ErrorIntervalLinkUp |
This indicates the duration of the measure interval in seconds for the ATM header error counter. That is used for calculating an average, which is then compared with the imaGroupErrorsLinkUp value. Range: 15 to 3600 |
MinLinkDownTime |
This indicates the minimum waiting time in seconds before a link can be enabled again, after it has been inhibited. Range: 0 to 3600 |