Introduction |
This workshop describes how to integrate the elmeg hybird 120™ into an existing network. An elmeg IP1x0™ telephone and an elmeg S5x0™ telephone are used on the system.
The first example describes how to integrate the elmeg hybird 120™ into an existing network with a gateway, e.g. bintec RS 232bw™.
![]() |
Note |
---|---|
The DHCP Server function of the elmeg hybird 120™ telephone system must be disabled in this example. |
Example scenario
Existing network with bintec RS232 bw™ gateway, as of system software version 9.1.2
An ISDN point-to-multipoint connection (e.g. Telekom)
An elmeg hybird 120j™ as of system software version 9.1, Rev. 2
An elmeg IP120™ telephone as of firmware version 01.00.04
An elmeg C560™ telephone as of firmware version 1.400
Connect the elmeg hybird 120j™ to all terminals (PC, telephones) and connections (ADSL splitter and ISDN-NTBA) as indicated in the circuit diagram
The bintec RS232bw™ gateway is used as a DHCP and DNS server in the network.
The second example describes how to integrate the elmeg hybird 120™ into an existing network with a Windows Server.
![]() |
Note |
---|---|
The DHCP Server function of the elmeg hybird 120™ telephone system must be disabled in this example. |
Example scenario
Existing network with Windows Server 2008 and a bintec RS232bw™ gateway
An ISDN point-to-multipoint connection (e.g. Telekom)
An elmeg hybird 120j™ as of system software version 9.1, Rev. 2
An elmeg IP120™ telephone as of firmware version 01.00.04
An elmeg C560™ telephone as of firmware version 1.400
Connect the elmeg hybird 120j™ to all terminals (PC, telephones) and connections (ADSL splitter and ISDN-NTBA) as indicated in the circuit diagram
The Windows Server 2008 is used as a DHCP and primary DNS server in the network
The bintec RS232bw™ gateway is used as a secondary DNS server in the network
The elmeg hybird 120j™ is used as a time server in the network.
The third example describes how to connect an elmeg hybird 120j™ to an ISDN point-to-multipoint connection and an ADSL Internet connection using the integrated ADSL/ADSL2+ modem.
In doing so, the provisioning of the elmeg IP1x0™ telephone is realised using the internal DHCP server of the elmeg hybird 120™.
Example scenario
An ADSL/ADSL2+ connection (e.g. Telekom)
An ISDN point-to-multipoint connection (e.g. Telekom)
An elmeg hybird 120j™ as of system software version 9.1, Rev. 2
An elmeg IP120™ telephone as of firmware version 01.00.04
An elmeg C560™ telephone as of firmware version 1.400
Connect the elmeg hybird 120j™ to all terminals (PC, telephones) and connections (ADSL splitter and ISDN-NTBA) as indicated in the circuit diagram
The elmeg hybird 120j™ is used as a DHCP, DNS and time server in the network.
The GUI™ (Graphical User Interface) is used for configuring here.
Copyright© Version 01/2020 bintec elmeg GmbH |