Configuration of the port

The DMZ is set up by dividing the four switch ports of the bintec be.IP™ into two interfaces.

Go to the following menu to assign the ports to the interfaces:

  1. Go to Physical Interfaces -> Ethernet Ports-> Port Configuration.

Physical Interfaces -> Ethernet Ports-> Port Configuration

Proceed as follows to assign the ports to interfaces:

  1. Under Ethernet Interface Selection select en1-0 for the Switch Ports 1 and 2 from the dropdown menu.

  2. Select en1-1 for the Switch Ports 3 and 4.

  3. Confirm with OK.

In the IP Configuration menu, you can assign IP addresses to the ports.

  1. Go to LAN -> IP Configuration -> Interfaces -> <en1-0> .

LAN -> IP Configuration -> Interfaces -> <en1-0> -> .

Proceed as follows:

  1. Leave Address Mode set to Static . The interface is assigned a static IP address.

  2. In IP Address / Net Mask enter the IP address and the subnet mask, here 192.168.100.1 and 255.255.255.0 .

  3. Leave Interface Mode set to Untagged . The interface is not assigned for a specific purpose.

  4. Confirm with OK.

Since your device can no longer be accessed by administration at the previous IP address, but only at the new IP address 192.168.100.1 , you must reconnect to the GUI™. To do this, enter the new IP address 192.168.100.1 in the address bar of your browser and log in again.

Proceed as follows for interface en1-1 :

  1. For en1-1 go to LAN -> IP Configuration -> Interfaces -> <en1-1>.

  2. Click the icon.

  3. Leave Address Mode set to Static .

  4. In IP Address / Net Mask enter the IP address and the subnet mask, here 192.168.200.2 and 255.255.255.0 .

  5. Leave Interface Mode set to Untagged .

  6. Confirm with OK.

If no IP address is entered, click Add for the IP address / Netmask. An input field appears for the IP address where you can assign the IP address and subnet mask.