Setting the initiator |
The status of the function key as on or off must be configured as an Trigger. Go to the Local Services->Scheduling->Trigger->New menu.
Local Services->Scheduling->Trigger->New
Proceed as follows:
Enter any Description for the event list, in this case Key status .
Under Event Type select the Function Button option.
Set the Function Button Status to On .
Press OK to confirm your entries.
![]() |
Note |
---|---|
The function key does not change the status between on and off every time it is actuated, but also changes the status depending on the time difference between presses! |
If actuated for more than one second, but less than three, then the status is on . Actuation longer than three seconds sets the key status to off .
Unintended actuation or so-called "toggling" between statuses is therefore avoided.
Copyright© Version 08/2020 bintec elmeg GmbH |